Page 10 of 28
DIGITAL SETUP MENU (Digital 1 and Digital 2)
VELOCITY
PULSES PER METRE
LONG ACC / LAT ACC
MAX VALUE
LONG ACC / LAT ACC
MAX FREQUENCY
Press’■’ and then use the ‘◄’
and ‘►’ buttons to select from:
Velocity
Long ACC
Lat ACC
Press’■’ and then use the ‘◄’
and ‘►’ buttons to set the
number of pulses per metre.
Then press ’■’ to confirm.
0.1-120 pulses per metre in 0.1
steps
Press’■’ and then use the ‘◄’
and ‘►’ buttons to set the level
of the maximum Velocity.
Then press ’■’ to confirm.
0-400km/h in 0.1km/h steps
Press’■’ and then use the ‘◄’
and ‘►’ buttons to set the level
of the maximum Long ACC or
Lat ACC level.
Then press ’■’ to confirm.
0.5g to 2g in 0.1 g steps
Press’■’ and then use the ‘◄’
and ‘►’ buttons to set the
frequency of the maximum Long
ACC or Lat ACC level.
Then press ’■’ to confirm.
1-50kHz in 0.1kHz steps
Press’■’ and then use the ‘◄’
and ‘►’ buttons to set a test
value that the Digital output will
simulate. Then press ’■’ to quit.
Press’■’ to exit the digital setup
menu and cause the settings to
be saved in EEPROM
ANALOGUE SETUP MENU (Analogue 1 and Analogue 2)
VALUE @ -5V (0V for
Velocity)
Press’■’ and then use the ‘◄’
and ‘►’ buttons to select from:
Velocity
Long ACC
Lat AC
Press’■’ and then use the ‘◄’
and ‘►’ buttons to set the
Velocity, Long ACC or Lat ACC
level to represent +5V. Then
press ’■’ to confirm.
1-400km/h in 1km/h steps, or
-1g to 2g in 0.1 g steps
Press’■’ and then use the ‘◄’
and ‘►’ buttons to set the
Velocity, Long ACC or Lat ACC
to represent 0V (velocity) or -5V
(Lat ACC & Long ACC).
Then press ’■’ to confirm.
0-399km/h in 1km/h steps, or
-2g to 1g in 0.1g steps
Press’■’ and then use the ‘◄’
and ‘►’ buttons to set a test
value that the analogue output
will simulate.
Then press ’■’ to quit.
Press’■’ to exit the analogue
setup menu and cause the
settings to be saved in EEPROM